ELGO Electronic P40-SN002 Series Manuale di Servizio

Navigare online o scaricare Manuale di Servizio per Apparecchiature di registrazione ELGO Electronic P40-SN002 Series. ELGO Electronic P40-SN002 Series Technical data [en] Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 46
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Operation Manual
Series P40-SN002
Application metal shears
Programmable controller
LCD Display
Simple handling
Manual inching function
Single set operation
Program memory
Digital outputs
Analog Output
Vedere la pagina 0
1 2 3 4 5 6 ... 45 46

Sommario

Pagina 1 - Series P40-SN002

Operation Manual Series P40-SN002 Application metal shears Programmable controller  LCD Display  Simple handling  Manual inching functi

Pagina 2 - Content

Product Features - 10 - 4. Product Features Essential features:  Analog or digital outputs for 1 - 3 speed operation  16 free programmab

Pagina 3

Technical Data - 11 - 5. Technical Data P40 – ELGO-position controller Input supply voltage 24 VDC Power input 24 VDC; max. 150 mA (no-load

Pagina 4 - 1. General Information

Technical Data - 12 - 5.1. Dimensions

Pagina 5

Configuration and Functions - 13 - 6. Configuration and Functions 6.1. Elements 6.1.1. Control Elements 6.1.2. Display

Pagina 6

Configuration and Functions - 14 - 6.1.3. Function of Keys Change Operation mode between „Manual“ and „Single“ Operation Mode “Program”

Pagina 7 - 2. Safety

Configuration and Functions - 15 - 6.2. Menu, sections and parameters Main menu Due to the display size only five menu levels are visible.

Pagina 8 - 3. Transport and Storage

- 16 - 6.2.1. Axis Menu / Distances Relevant distances for the axes can be set in this menu. Configuration and Functions Axis distances

Pagina 9 - 3.4. Storage

Configuration and Functions - 17 - 6.2.1.1. Distance / Longitudes Parameters Slow speed/Creep speed/Correction Slow speed/slow speed (r) =

Pagina 10 - 4. Product Features

Configuration and Functions - 18 - Positioning with two speeds Slow speed = Creep speed > Correction stop Slow speed/Slow speed (r) =

Pagina 11 - 5. Technical Data

Configuration and Functions - 19 - Tolerance window It is possible to enter a value in this register that represents an acceptable tolerance.

Pagina 12 - 5.1. Dimensions

Contents - 2 - Content 1. General Information ...

Pagina 13 - 6.1. Elements

Configuration and Functions -20- Software-end position MIN/MAX These two values can be used if no mechanical limit switches are present or addit

Pagina 14

Configuration and Functions -21- 6.2.2. Axis menu / times The times relevant for the respective axes can be entered from 0.1 to 99.9 seconds.

Pagina 15

Configuration and Functions -22- Parameter of time Position reached The signal is based on a variable time during input of a time value or stat

Pagina 16

Configuration and Functions -23- 6.2.3. Axis menu / analog The axis relevant analog parameters can be set in this menu.

Pagina 17

Configuration and Functions -24- 6.2.3.1. Analog parameters Velocity The maximum speed is set in this register, in rpm. The speed is monitored

Pagina 18 - Creep speed

Configuration and Functions -25-D-portion Differential voltage: setting 1...1000 General: The D-controller (differential controller) provides t

Pagina 19

Configuration and Functions -26- 6.2.4. Axis menu / General System relevant general parameters can be entered in this register.

Pagina 20 - ]pulses[

Configuration and Functions -27- 6.2.4.1. System parameters Positioning measurement system The type of measurement system is defined in this

Pagina 21

Configuration and Functions -28-  Drive signals = Mode 3 2 speeds speed = output signals 2 + 3 output 4 set direction reverse Output sig

Pagina 22

Configuration and Functions -29-  Drive signals = Mode 6 3 speeds Binary coded output 1 = forward output 4 = backward outputs 2+3 = spe

Pagina 23

Contents - 3 - 7. Operation ...

Pagina 24

Configuration and Functions -30-Mode reference The mode for referencing is defined in this parameter. Mode 1 = Calibration through reference para

Pagina 25

Configuration and Functions -31-6.2.5 Material Table In this table the material specific experienced values for cut angle and gut gap can be ent

Pagina 26

Configuration and function -32- 6.2.6 Menu / System Adjustment Access to system parameters. Default Parameter Reset to factory paramete

Pagina 27

Configuration and Functions -33- Language  German  English Axes active  Backgauge + Gap + Angle  Backgauge + Gap  Backgauge + Ang

Pagina 28

Configuration and Functions -34- 6.3. Machine setting ATTANTION! First check end-switch function! 6.3.1. Gap Setup (Cut gap) Minimum gap

Pagina 29

-35-Configuration of inputs and outputs With the controller P40 it is possible to configure feely the inputs and outputs with their associated l

Pagina 30

Operation -36- 7. Operation 7.1 Operation Modes 7.1.1 Manual mode With the keys F1 & F3 the axis shown in the display can be driven manuall

Pagina 31 - Advert!

Operation -37-7.1.3.2. Handle of a program The program mode can be select directly by using the program button. First, choose a program by enter

Pagina 32

Operation -38- 7.2 Connector pin assignment ST1 = Encoder input Backgauge ST2 = Encoder input Angle and Gap ST3/ST4 = Digital Inp

Pagina 33

Operation -39- 7.2.1 Overview Terminal Assignment ST1 Encoder Backgauge ST2 Encoder Gap and Angle 1 GND1 GND2 5VDC/24VDC2 3,3VDC

Pagina 34 - 6.3. Machine setting

- 4 - 1. General Information 1.1. Information Operation Manual The manual contains important information regarding the handling of the contr

Pagina 35

Operation -40-7.3 Diagnostics The modules for inspecting, maintenance, control and safety/security are provided in this register: (1) Input te

Pagina 36 - 7. Operation

Interferences -41-8. Interferences The following chapters describe possible causes for malfunction and the instructions to correct them. If you

Pagina 37 - 7.1.4 Reference

Interferences -42- Shielding: All external signal wires have to be installed shielded: 1. Rotary encoder wires and analog input wires 2. Wires

Pagina 38

Interferences -43-8.4 EMC information A trouble-free operation of the control devices of the company ELGO Electric GmbH can only be guaranteed

Pagina 39

Maintenance -44- 9 Maintenance The unit works maintenance-free.

Pagina 40 - 7.3 Diagnostics

Type Designation -45- 10 Type Designation P40 – XXX – 024 – XX – XX - XXXX Positioning controller Single axis with program memor

Pagina 41 - 8. Interferences

Accessories -46- 11 Accessories NG 13.0 Power supply Primary: 115/230 V AC Secondary: 24 V DC/600 mA Imprint Relay outputs o

Pagina 42

- 5 - Hints and commendations ADVERT! ...highlights helpful hints and recommendations for efficient and failure-free operation. Specif

Pagina 43 - 8.4 EMC information

General Information - 6 - 1.4. Demounting and Disposal Unless otherwise authorized, dispose the item considering the safety instructions. Bef

Pagina 44 - 9 Maintenance

- 7 - 2. Safety 2.1. General Cause of Risks This chapter gives an overview about all important safety aspects to guarantee an optimal prot

Pagina 45 - 10 Type Designation

Conventional use, Transport, Storage - 8 - 2.3. Conventional Use The controller P40 is for the limited purpose as described in this manual:

Pagina 46 - 11 Accessories

Conventional use, Transport, Storage - 9 - 3.3. Check of Transport Examine delivery immediately after receiving for completeness and transport

Commenti su questo manuale